Smart Balancing

Measuring Case – Single or Double Sensor

Measuring Case 

  • Carrying Case
  • Measuring Sensor 2 pcs
  • Charger to Sensor
  • Measuring hoses 4 pcs
  • Measuring needles 4 pcs
  • DPT compined DP & Temperature probe 2 pcs
  • Allen keys
  • Industrial Smartphone 
  • Industrial Tablet
  • Charger to Smartphone & Tablet
  • Operation Manual
  • USB stick with manuals & support program
  • Calibration Certificate
  • Flex 2 Standard Balancing program (Android)
  • Flex 4 Professional Balancing program (Android)
  • Flex 4 Professional Balancing program (Windows)
  • Project, valve, measurement & balancing protocol administration program (Windows)

Measurement Range 

  • Differential Pressure: 0-1 000 kPa
  • Static pressure: <1 000 kPa
  • System Temp: -30 – +120°C

Measurement deviation 

  • Differential Pressure: <0,1 % of Full Scale (of calibration pressure, 100 kPa)<1 000 kPa
  • Flow: as for differential pressure + valve deviation
  • Temperature: <0,2°C

Battery capacity, operating and charge time Sensor 

  • Battery Capacity: 7 200mAh
  • Operating Time: 35 hours, continuous duty
  • Charging Time: 6 hours

 Ambient temperature for the instrument 

  • During operation and charging: 0 – 40°C
  • During storage: -20°C – 60°C
  •  Humidity: Ambient humidity: max 90 % RH
  • Weight Sensor: 540 gr. Complete Case: 2,8kg
  • Open Space Range: >200 m. >500 m with antenna (option)
  • IP-class Sensor: IP65

 

 

Smart Balancing

Measuring Case – Dual Sensors 

Measuring Case 

  • Carrying Case
  • Measuring Sensor
  • Charger to Sensor
  • 2 pcs Measuring hoses
  • 2 pcs Measuring needles
  • Allen keys
  • Operation manual
  • USB stick with manuals & Balancing programs
  • Calibration certificate

 

 

Measurement Range 

  • Differential Pressure: 0-1 000 kPa
  • Static pressure: <1 000 kPa
  • System Temp: -30 – +120°C

Measurement deviation 

  • Differential Pressure: <0,1 % of Full Scale (of calibration pressure, 100 kPa)<1 000 kPa
  • Flow: as for differential pressure + valve deviation
  • Temperature: <0,2°C

Battery capacity, operating and charge time Sensor 

  • Battery Capacity: 7 200mAh
  • Operating Time: 35 hours, continuous duty
  • Charging Time: 6 hours

 Ambient temperature for the instrument 

  • During operation and charging: 0 – 40°C
  • During storage: -20°C – 60°C
  •  Humidity: Ambient humidity: max 90 % RH
  • Weight Sensor: 540 gr. Complete Case: 2,8kg
  • Open Space Range: >200 m. >500 m with antenna (option)
  • IP-class Sensor: IP65